      Middle voltage fuse link
      PRODUCT
      ■ H.V.C current-liniting fuses type W for transformer protection

      Applications
      H.V. HRC current-limiting fuses type S is mainly used in AC50HZ,rated voltage 3.6-10kv,rated current up to 200A circuit for protection transformers and power equipments from overload and short-circuit.It can also be used with load switch,vacuum contactor.
      It conforms to IEC282-1,GB15166.2 and DIN standard. 

      Design Features
      W type H.V HRC current-limiting fuses is bus-bar installation.the fuse link is fastened to the bus bar directly with bolts.It is small in volume,reliable in connection,The striker parallels to the fuse element made of pure silver.They are sealed in the fuse tube filled with chemically treated high-purity quartz sand.The fuse tube is made from heat resistant,high duty cermic or epoxy glass.When fault circuit happens,the fuse link melts,the high-resistant metal wire paralleling to fuse linsk melts immediately at the appearance of the arc,and the striker jumps out to push the chained equipment contact,signaling the melting or automatically cutting the circuit.A/b type H.V HRC current-limiting fuses has many merits and high current-liming ability,high breaking capacity,quick and punctual in action,reliable in performance.

      Mode and implication

      Dasic data 
      models
      rated voltage(KV)
      rated current of the fuse links(A)
      rated breaking current(KA)
      dimensions(mm)
      weight KG
      order NO.
      foreign
      department
      φD
      L
      WDF.O
      XRNM1
      3.6
      50
      50
      51
      254
      1.4
      9018050
      WDF.O
      XRNM1
      3.6
      63
      50
      51
      254
      1.4
      9018063
      WDF.O
      XRNM1
      3.6
      80
      50
      51
      254
      1.4
      9018080
      WDF.O
      XRNM1
      3.6
      100
      50
      51
      254
      1.4
      9018100
      WDF.O
      XRNM1
      3.6
      125
      50
      51
      254
      1.4
      9018125
      WFF.O
      XRNM1
      3.6
      125
      50
      76
      254
      2.8
      9019125
      WFF.O
      XRNM1
      3.6
      160
      50
      76
      254
      2.8
      9019160
      WFF.O
      XRNM1
      3.6
      200
      50
      76
      254
      2.8
      9019200
      WKF.O
      XRNM1
      3.6
      250
      50
      76
      254
      2.8
      9019250
      WKF.O
      XRNM1
      3.6
      315
      50
      76
      254
      2.8
      9019350
      WKF.O
      XRNM1
      3.6
      355
      50
      76
      254
      2.8
      9019355
      WKF.O
      XRNM1
      3.6
      400
      50
      76
      254
      2.8
      9019400
      WFN.O
      XRNM1
      7.2
      25
      40
      76
      403
      4.15
      9020025
      WFN.O
      XRNM1
      7.2
      31.5
      40
      76
      403
      4.15
      9020031
      WFN.O
      XRNM1
      7.2
      40
      40
      76
      403
      4.15
      9020040
      WFN.O
      XRNM1
      7.2
      50
      40
      76
      403
      4.15
      9020050
      WFN.O
      XRNM1
      7.2
      63
      40
      76
      403
      4.15
      9020063
      WFN.O
      XRNM1
      7.2
      80
      40
      76
      403
      4.15
      9020080
      WFN.O
      XRNM1
      7.2
      100
      40
      76
      403
      4.15
      9020100
      WFN.O
      XRNM1
      7.2
      125
      40
      76
      403
      4.15
      9020125
      WFN.O
      XRNM1
      7.2
      160
      40
      76
      403
      4.15
      9020160
      WKN.O
      XRNM1
      7.2
      200
      40
      76
      403
      4.15
      9020200
      WKN.O
      XRNM1
      7.2
      224
      40
      76
      403
      4.15
      9020224
      XRNM1
      10
      25
      40
      76
      600
      5.26
      9021025
      XRNM1
      10
      31.5
      40
      76
      600
      5.26
      9021031
      XRNM1
      10
      40
      40
      76
      600
      5.26
      9021040
      XRNM1
      10
      50
      40
      76
      600
      5.26
      9021050
      XRNM1
      10
      63
      40
      76
      600
      5.26
      9021063
      XRNM1
      10
      80
      40
      76
      600
      5.26
      9021080
      XRNM1
      10
      100
      40
      76
      600
      5.26
      9021100
      XRNM1
      10
      125
      40
      76
      600
      5.26
      9021125
      XRNM1
      10
      160
      40
      76
      600
      5.26
      9021160
      XRNM1
      10
      200
      40
      76
      600
      5.26
      9021200
      XRNM1
      10
      224
      40
      76
      600
      5.26
      9021224

      Note:under stipulated condition,min.breaking current of fuses could be as high as 2.5-3times than rated current.
      7.3KV>224A it is of dual-tube body
      3.6KV>400A it is of dual-tube body

      Dimension of motor protection fuse type W for busbar installation(mm)see fig.SS-5021、5020
      models
      rated voltage(KV)
      rated current of the fuse links(A)
      A
      B
      C
      G
      E
      L
      φD
      order NO.
      foreign
      department
      WFF.O
      XRNM2
      3.6
      50
      390
      312
      150
      140
      246
      254
      76
      9025050
      WFF.O
      XRNM2
      3.6
      63
      390
      312
      150
      140
      246
      254
      76
      9025063
      WFF.O
      XRNM2
      3.6
      80
      390
      312
      150
      140
      246
      254
      76
      9025080
      WFF.O
      XRNM2
      3.6
      100
      390
      312
      150
      140
      246
      254
      76
      9025100
      WFF.O
      XRNM2
      3.6
      125
      390
      312
      150
      140
      246
      254
      76
      9025125
      WKF.O
      XRNM2
      3.6
      125
      390
      312
      150
      140
      246
      254
      76
      9026125
      WKF.O
      XRNM2
      3.6
      160
      390
      312
      150
      140
      246
      254
      76
      9026160
      WKF.O
      XRNM2
      3.6
      200
      390
      312
      150
      140
      246
      254
      76
      9026200
      WKF.O
      XRNM2
      3.6
      250
      390
      312
      150
      140
      246
      254
      76
      9026250
      WKF.O
      XRNM2
      3.6
      315
      390
      312
      150
      140
      246
      254
      76
      9026315
      WKF.O
      XRNM2
      3.6
      355
      390
      312
      150
      140
      246
      254
      76
      9026355
      WKF.O
      XRNM2
      3.6
      400
      390
      312
      150
      140
      246
      254
      76
      9026400
      WFN.O
      XRNM2
      7.2
      25
      500
      361
      340
      160
      266
      403
      76
      9027025
      WFN.O
      XRNM2
      7.2
      31.5
      500
      361
      340
      160
      266
      403
      76
      9027031
      WFN.O
      XRNM2
      7.2
      40
      500
      361
      340
      160
      266
      403
      76
      9027040
      WFN.O
      XRNM2
      7.2
      50
      500
      361
      340
      160
      266
      403
      76
      9027050
      WFN.O
      XRNM2
      7.2
      63
      500
      361
      340
      160
      266
      403
      76
      9027063
      WFN.O
      XRNM2
      7.2
      80
      500
      361
      340
      160
      266
      403
      76
      9027080
      WFN.O
      XRNM2
      7.2
      100
      500
      361
      340
      160
      266
      403
      76
      9027100
      WFN.O
      XRNM2
      7.2
      125
      500
      361
      340
      160
      266
      403
      76
      9027125
      WFN.O
      XRNM2
      7.2
      160
      500
      361
      340
      160
      266
      403
      76
      9027160
      WFN.O
      XRNM2
      7.2
      200
      500
      361
      340
      160
      266
      403
      76
      9027200
      WFN.O
      XRNM2
      7.2
      224
      500
      361
      340
      160
      266
      403
      76
      9027224
      XRNM2
      10
      25
      690
      659
      350
      160
      266
      600
      76
      9028025
      XRNM2
      10
      31.5
      690
      659
      350
      160
      266
      600
      76
      9028031
      XRNM2
      10
      40
      690
      659
      350
      160
      266
      600
      76
      9028040
      XRNM2
      10
      50
      690
      659
      350
      160
      266
      600
      76
      9028050
      XRNM2
      10
      63
      690
      659
      350
      160
      266
      600
      76
      9028063
      XRNM2
      10
      80
      690
      659
      350
      160
      266
      600
      76
      9028080
      XRNM2
      10
      100
      690
      659
      350
      160
      266
      600
      76
      9028100
      XRNM2
      10
      125
      690
      659
      350
      160
      266
      600
      76
      9028125
      XRNM2
      10
      160
      690
      659
      350
      160
      266
      600
      76
      9028160
      XRNM2
      10
      200
      690
      659
      350
      160
      266
      600
      76
      9028200
      XRNM2
      10
      224
      690
      659
      350
      160
      266
      600
      76
      9028224

      Dimensions





      Selection for W type motor current-limiting fuse

      When started with full voltage,rated current=twice of loade d motor current;when started under other circumstances,rated current=1.5 times of loaded motor current.For directly started motor,fuses of proper rated curren should be selected according to the following formula;1.5 times of loaded motor current.For directly started motor,fuses of proper rated current should be selected according to the following formula:
      Iy=N·In·φ
      Iy--starting current 
      N--ratio fo starting current and loaded cruuent,usually N∽6
      In--loaded motor current
      φ--comprehensive coefficient,see the table below

      φ comprehensive coefficient
      start times
      2
      4
      8
      16
      φ
      1.7
      1.9
      21
      2.3

      Refer to time-current characteristic diagram forselection of proper H.V.Fuse link,rated current of fuse link should be more than 1.3 times than loaded motor current.

      Characteristice curve 


       
      Copyright © 2009 Sanshi Eletric Co., Ltd.
      TEL::+86-577-27870116    FAX :+86-577-27881111
      浙ICP備10028708號
      Technical support: jksm
      寂寞的大乳老师中文字幕

        <sub id="g4jni"></sub>
        <sub id="g4jni"></sub>

        <sub id="g4jni"></sub><thead id="g4jni"><li id="g4jni"><em id="g4jni"></em></li></thead>

        <delect id="g4jni"><ruby id="g4jni"></ruby></delect>
          <acronym id="g4jni"><li id="g4jni"><address id="g4jni"></address></li></acronym>

            <thead id="g4jni"></thead>