■ H.V.HRC current-liniting fuses type S for transformer protection
Applications H.V. current-limiting fuses type S is mainly used in AC50HZ,rated voltage 3.6-40.5kv,rated current up to 200A circuit for protection transformers and power equipments from overload and short-circuit.It can also be used with load switch,vacuum contactor. It conforms to IEC282-1,GB15166.2 and DIN standard.
Design Features S type H.V.HRC current-limiting fuses is insert installation.The striker parallels to the fuseelement made of pure silver.It is sealed in the fuse tube filled with chemically treated high-purity quartz sand.The fuse tube is made from beat resistance,high duty ceramic or expoxy glass when fault circuit happens,the fuse link melts,the high-resistant metal wire paralleling to fuse links melts immediately at the appearance of the arc,and the striker jumps out to push the chained equipment contact,signaling the melting automatically cuttng the circuit.The striker has spring type and powder type.Spring type striker use energy released by spring to push the strker;Power type striker use high pressure caused by the lighting powder to push the striker,S type H.V.HRC current-limiting fuses has many merits as high current-limintingh ablilty,high breaking capacity,quick and punctual in action,reliable in performance.
Mode and implication
Dasic data
models
rated voltage(KV)
rated current of the fuse links(A)
rated breaking current(KA)
dimensions(mm)
weight KG
order NO.
foreign
department
φD
L
SDO.J
XRNT1
3.6
6.3
31.5
51
192
1.12
9001006
SDO.J
XRNT1
3.6
10
51
192
1.12
9001010
SDO.J
XRNT1
3.6
16
51
192
1.12
9001016
SDO.J
XRNT1
3.6
20
51
192
1.12
9001020
SDO.J
XRNT1
3.6
25
51
192
1.12
9001025
SDO.J
XRNT1
3.6
31.5
51
192
1.12
9001031
SDO.J
XRNT1
3.6
40
51
192
1.12
9001040
SDL.J
XRNT1
7.2
6.3
51
292
1.47
9002006
SDL.J
XRNT1
7.2
10
51
292
1.47
9002010
SDL.J
XRNT1
7.2
16
51
292
1.47
9002016
SDL.J
XRNT1
7.2
20
51
292
1.47
9002020
SDL.J
XRNT1
7.2
25
51
292
1.47
9002025
SDL.J
XRNT1
7.2
31.5
51
292
1.47
9002031
SDL.J
XRNT1
7.2
40
51
292
1.47
9002040
SDL.J
XRNT1
7.2
50
51
292
1.47
9002050
SDL.J
XRNT1
7.2
63
51
292
1.47
9002063
SFL.J
XRNT1
7.2
80
76
292
3.15
9002080
SFL.J
XRNT1
7.2
100
76
292
3.15
9002100
SFL.J
XRNT1
7.2
125
76
292
3.15
9002125
SFL.J
XRNT1
7.2
160
76
292
3.15
9002160
SDL.J
XRNT1
12(10)
6.3
51
292
1.47
9003006
SDL.J
XRNT1
12(10)
10
51
292
1.47
9003010
SDL.J
XRNT1
12(10)
16
51
292
1.47
9003016
SDL.J
XRNT1
12(10)
20
51
292
1.47
9003020
SDL.J
XRNT1
12(10)
25
51
292
1.47
9003025
SDL.J
XRNT1
12(10)
31.5
51
292
1.47
9003031
SDL.J
XRNT1
12(10)
40
51
292
1.47
9003040
SFL.J
XRNT1
12(10)
50
76
292
3.15
9003050
SFL.J
XRNT1
12(10)
63
76
292
3.15
9003063
SFL.J
XRNT1
12(10)
71
76
292
3.15
9003071
SFL.J
XRNT1
12(10)
80
76
292
3.15
9003080
SFL.J
XRNT1
12(10)
100
76
292
3.15
9003100
SKL.J
XRNT1
12(10)
125
76
292
3.15
9003125
SXL.J
XRNT1
12(10)
160
88
292
4.15
9003160
SXL.J
XRNT1
12(10)
200
88
292
4.15
9003200
SDM.J
XRNT1
24(20)
6.3
51
442
2.7
9004006
SDM.J
XRNT1
24(20)
10
51
442
2.7
9004010
SDM.J
XRNT1
24(20)
16
51
442
2.7
9004016
SDM.J
XRNT1
24(20)
20
51
442
2.7
9004020
SDM.J
XRNT1
24(20)
25
51
442
2.7
9004025
SDM.J
XRNT1
24(20)
31.5
51
442
2.7
9004031
SDM.J
XRNT1
24(20)
40
51
442
2.7
9004040
SFM.J
XRNT1
24(20)
50
76
442
4.5
9004050
SFM.J
XRNT1
24(20)
63
76
442
4.5
9004063
SFM.J
XRNT1
24(20)
71
76
442
4.5
9004071
SFM.J
XRNT1
24(20)
80
76
442
4.5
9004080
SFM.J
XRNT1
24(20)
100
76
442
4.5
9004100
SKM.J
XRNT1
24(20)
125
76
442
4.5
9004125
SXM.J
XRNT1
24(20)
160
88
442
5.4
9004160
SDQ.J
XRNT1
40.5(36)
3.15
51
537
2.9
9005003
SDQ.J
XRNT1
40.5(36)
6.3
51
537
2.9
9005006
SDQ.J
XRNT1
40.5(36)
10
51
537
2.9
9005010
SDQ.J
XRNT1
40.5(36)
16
51
537
2.9
9005016
SDQ.J
XRNT1
40.5(36)
20
51
537
2.9
9005020
SDQ.J
XRNT1
40.5(36)
25
51
537
2.9
9005025
SFQ.J
XRNT1
40.5(36)
31.5
76
537
5.51
9005031
SFQ.J
XRNT1
40.5(36)
40
76
537
5.51
9005040
SXQ.J
XRNT1
40.5(36)
50
76
537
6.5
9005050
SFQ.J
XRNT1
40.5(36)
63
88
537
6.5
9005063
SFQ.J
XRNT1
40.5(36)
80
88
537
6.5
9005080
SXQ.J
XRNT1
40.5(36)
100
88
537
6.5
9005100
Note:under stipulated condition,min.breaking current of fuses could be as high as 2.5-3times than rated current.